Fixed X Ray Machine

In this products group you will see STAR NUKE Fixed X Ray Machines. All Machines are AERB APPROVED. Machines specifitions are describing in their details or their table of details. Check now 

STARNUKE-HF100R 5 KW High Frequency 100 mA Fixed X Ray Machine

Request Callback

₹ 424098 Get Latest Price

Product Brochure
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeHigh Frequency
Tube TypeStationary Anode
Power Supply Volts220 V
Peak Kilo Voltage100 kvP
Generator Power5 KW
Table TypeTransparent Polycarbonate Horizonal Bucky Table, Dimension-76 x26 x29.5 Inch, Load-200kg
Table Base Elevating Range3 Feet
Ceiling SuspensionFloor to ceiling

Minimum order quantity: 1 Piece

STARNUKE offers 100 mA High Frequency Fixed X Ray Machine with Bucky Table and GRID price is Rs. 292240 which is including GST. STARNUKE HF100R provides high end image quality and resolution to meet best diagnostic radiology investigations.

Specifications:

100mA Fixed High Frequency X Ray Machine

  • Single integrated console system.
  • Digital Display for display of X-ray parameters of KV & mAs.
  • mA, KV & mAs increase and decrease switches.
  • Ready and X-Ray on switch with Indicators.
  • Bucky Selection Switch
  • Tube current: 100 mA
  • Tube voltage: 40-100 kVp
  • Focal Spot    : 2.6 mm2
  • mAs Range   : 1- 250 mAs
  • X-ray tube    : imported rotating  anode
  • Collimator    : Manual light beam diaphragm
  • Power supply: Single Phase 230 + 10 V, 50 Hz
  • Inverter Frequency: 40 KHz            

 

Transparent HBT - Horizonal Bucky Table

  • Dimension :"76 x26 x29.5"inch
  • Load:200kg
  • Surface: Polycarbonates (PC)
  • Vertical Bucky with Stand
  • Power Supply: 230V
  • Bucky Space: 18 X 18           
  • Bucky Stand Height: 77inch

Customized for user friendly applications:

  • Rails for horizontal movement of the column.
  • Tube stand and Tube head rotatable in 360.
  • smooth movement horizontally and vertically.
  • separate locking system of tube head, carriage arms and base ensure stable machine during exposure.
  • compatible with horizontally as well as multi cone table.

Fixed 100 mA X Ray Machine STARNUKE-FX100 Line Frequency

Request Callback

₹ 185170 Get Latest Price

Product Brochure
BrandSTARNUKE
Model Name/Number100 mA Xray Machine STARNUKE FX100
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeLine Frequency
Tube TypeRotating Anode
Power Supply Volts220 V
Power Supply Frequency50 Hz
Peak Kilo Voltage100 kvP
Generator Power8 KW

Minimum order quantity: 1 Piece

STARNUKE FX100 with HBT combo set up comprise of

100mA Fixed Line Frequency X Ray Machine

Transparent HBT - Horizonal Bucky Table

 

Specifications:

1.   100mA Fixed Line Frequency

  • Radiography             : 100 mA at 100 kVp
  • Tube current                      : F(0-3 mA), 25 mA, 50 mA, 75 mA &100 Ma
  • Tube voltage                      : 40-100 kVp (15 steps)
  • Timer                       : 0.02-5 seconds (24Steps)
  • X-ray tube                :Indian / imported stationery anode
  • Collimator                          :Manual light beam diaphragm
  • Power supply            :Single Phase 230 + 10 V, 50 Hz
  • Rectification                       :Full wave rectified using silicon rectifiers.

2.   Transparent HBT - Horizonal Bucky Table

Dimension :"76 x26 x29.5"inch

Load:200kg

Surface: Polycarbonates (PC)

X Ray Machine 300 mA High Frequency X Ray Machine with Bucky Table

Request Callback

₹ 509956 Get Latest Price

Product Brochure
BrandSTARNUKE
Model Name/NumberSTARNUKEHF300
Generator Capacity300 mA
Machine TypeFixed (Stationary)
Generator TypeHigh Frequency
Tube TypeRotating Anode
Power Supply Volts440 V
Power Supply Frequency50 Hz
Peak Kilo Voltage100 kvP
Generator Power20 KW

Minimum order quantity: 1 Piece

X Ray STARNUKE HF300 AERB Approved Medical X Ray is best fit radiology solution for multibed hospital or setting up high patient workload in diagnostic center. 

Combo set up comprise of;

  1. 300mA Fixed High Frequency X Ray Machine
  2. Transparent HBT - Horizonal Bucky Table

Specifications:

1.   300mA Fixed High Frequency X Ray Machine

  • Maximum Output Power :20 KW
  • Inverter Frequency :40 KHZ
  • Focal Spot : Large 2.0 mm x 2.0 mm                    : Small 1.0 mm x 1.0 mm
  • Monobloc’s kV Range :40kV to 125kV
  • Maximum mA :320mA
  • mAs Range :1 - 320 

Features:

  • Single integrated console system.
  • Digital Display for display of X-ray parameters of KV & mAs.
  • Option of selecting mA station.
  • mA, KV & mAs increase and decrease switches.
  • Ready and X-Ray on switch with Indicators.
  • Bucky Selection Switch.
  • Self-diagnostic Program with Indicators for Earth fault error, KV error, filament error & Tube’s Thermal Overload.
  • Anatomical Programming radiography (i.e. APR) in which KV & MAS are automatically selected depending upon the physique of the patient and part of the body to be X-rayed.
  • All anatomical Programming available.

2.   Transparent HBT - Horizonal Bucky Table

  • Dimension   :"76 x26 x29.5"inch
  • Load           :200kg
  • Surface       :Polycarbonates (PC)

100mA Fixed in Line Frequency FX100 X Ray Machine AERB approved

Request Callback

₹ 119196 Get Latest Price

Product Brochure
BrandStar Nuke
Model Name/NumberSTAR NUKE FX100
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeLine Frequency
Tube TypeStationary Anode
Power Supply Volts220 V
AERB ApprovedYes
Operation ModeManual
Technology TypeAnalog

Minimum order quantity: 1 Piece

Presenting Starnuke's Line Frequency 100 mA Fixed X-Ray Machine: this powerful but also reliable machine will ensure excellent image quality for any clinic or medical center looking for dependable and easy-to-operate diagnostic equipment.

The Starnuke 100 mA Fixed Diagnostic X-Ray Machine without HBT Table Line Frequency, made by us, offers the perfect tube head motion that comes with an instinctive user interface. It provides high-quality, high-resolution images for the most demanding needs of diagnostic radiology investigations. Due to these characteristics, it is the ideal machine for every hospital, clinic, and diagnostic center. 

Technical Specification

• Model: Starnuke 100 mA Fixed X-Ray Machine
• Radiography: 100 mA at 100 kVp
• Tube Current: F(0-3 mA), 25 mA, 50 mA, 75 mA & 100 mA
• Tube Voltage: 40-100 kVp (15 Steps)
• Timer: 0.02-5 Seconds (24 Steps)
• X-Ray Tube: Indian/Imported stationery anode
• Collimator: Manual light beam diaphragm
- Power Supply: Single Phase 230 + 10 V, 50 Hz 
- Rectification: Full wave rectified using silicon rectifiers  

Applications

1. Hospitals  
    For hospitals requiring an efficient and qualitative imaging system to assure proper diagnosis among the patients.

2. Clinics
Ideal for small to medium clinics where reliability and ease of operation are paramount in patient care.

3. Diagnostic Centers 
   It meets the high demand for diagnostic centers in order to provide fine resolution for accurate diagnoses.

4. Radiology Departments 
   This will be a good partner in the radiology departments since it improves the work of the workflow and enhances diagnostic capabilities.

 

100mA Fixed in Line Frequency X Ray Machine

Request Callback

₹ 119196 Get Latest Price

Product Brochure
BrandStar Nuke
Model Name/NumberSTAR NUKE FX100
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeLine Frequency
Tube TypeStationary Anode
Power Supply Volts220 V
AERB ApprovedYes
Operation ModeManual
Technology TypeAnalog

Minimum order quantity: 1 Piece

Presenting Starnuke's Line Frequency 100 mA Fixed X-Ray Machine: this powerful but also reliable machine will ensure excellent image quality for any clinic or medical center looking for dependable and easy-to-operate diagnostic equipment.

The Starnuke 100 mA Fixed Diagnostic X-Ray Machine without HBT Table Line Frequency, made by us, offers the perfect tube head motion that comes with an instinctive user interface. It provides high-quality, high-resolution images for the most demanding needs of diagnostic radiology investigations. Due to these characteristics, it is the ideal machine for every hospital, clinic, and diagnostic center. 

Technical Specification

• Model: Starnuke 100 mA Fixed X-Ray Machine
• Radiography: 100 mA at 100 kVp
• Tube Current: F(0-3 mA), 25 mA, 50 mA, 75 mA & 100 mA
• Tube Voltage: 40-100 kVp (15 Steps)
• Timer: 0.02-5 Seconds (24 Steps)
• X-Ray Tube: Indian/Imported stationery anode
• Collimator: Manual light beam diaphragm
- Power Supply: Single Phase 230 + 10 V, 50 Hz 
- Rectification: Full wave rectified using silicon rectifiers  

Applications

1. Hospitals  
    For hospitals requiring an efficient and qualitative imaging system to assure proper diagnosis among the patients.

2. Clinics
Ideal for small to medium clinics where reliability and ease of operation are paramount in patient care.

3. Diagnostic Centers 
   It meets the high demand for diagnostic centers in order to provide fine resolution for accurate diagnoses.

4. Radiology Departments 
   This will be a good partner in the radiology departments since it improves the work of the workflow and enhances diagnostic capabilities.

 

STARNUKE-FX100 100mA Fixed in Line Frequency X Ray Machine

Request Callback

₹ 119196 Get Latest Price

Product Brochure
BrandStar Nuke
Model Name/NumberSTAR NUKE FX100
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeLine Frequency
Tube TypeStationary Anode
Power Supply Volts220 V
AERB ApprovedYes
Operation ModeManual
Technology TypeAnalog

Minimum order quantity: 1 Piece

Presenting Starnuke's Line Frequency 100 mA Fixed X-Ray Machine: this powerful but also reliable machine will ensure excellent image quality for any clinic or medical center looking for dependable and easy-to-operate diagnostic equipment.

The Starnuke 100 mA Fixed Diagnostic X-Ray Machine without HBT Table Line Frequency, made by us, offers the perfect tube head motion that comes with an instinctive user interface. It provides high-quality, high-resolution images for the most demanding needs of diagnostic radiology investigations. Due to these characteristics, it is the ideal machine for every hospital, clinic, and diagnostic center. 

Technical Specification

• Model: Starnuke 100 mA Fixed X-Ray Machine
• Radiography: 100 mA at 100 kVp
• Tube Current: F(0-3 mA), 25 mA, 50 mA, 75 mA & 100 mA
• Tube Voltage: 40-100 kVp (15 Steps)
• Timer: 0.02-5 Seconds (24 Steps)
• X-Ray Tube: Indian/Imported stationery anode
• Collimator: Manual light beam diaphragm
- Power Supply: Single Phase 230 + 10 V, 50 Hz 
- Rectification: Full wave rectified using silicon rectifiers  

Applications

1. Hospitals  
    For hospitals requiring an efficient and qualitative imaging system to assure proper diagnosis among the patients.

2. Clinics
Ideal for small to medium clinics where reliability and ease of operation are paramount in patient care.

3. Diagnostic Centers 
   It meets the high demand for diagnostic centers in order to provide fine resolution for accurate diagnoses.

4. Radiology Departments 
   This will be a good partner in the radiology departments since it improves the work of the workflow and enhances diagnostic capabilities.

 

100mA Fixed in Line Frequency X Ray Machine STARNUKE

Request Callback

₹ 119196 Get Latest Price

Product Brochure
BrandStar Nuke
Model Name/NumberSTAR NUKE FX100
Generator Capacity100 mA
Machine TypeFixed (Stationary)
Generator TypeLine Frequency
Tube TypeStationary Anode
Power Supply Volts220 V
AERB ApprovedYes
Operation ModeManual
Technology TypeAnalog

Minimum order quantity: 1 Piece

Presenting Starnuke's Line Frequency 100 mA Fixed X-Ray Machine: this powerful but also reliable machine will ensure excellent image quality for any clinic or medical center looking for dependable and easy-to-operate diagnostic equipment.

The Starnuke 100 mA Fixed Diagnostic X-Ray Machine without HBT Table Line Frequency, made by us, offers the perfect tube head motion that comes with an instinctive user interface. It provides high-quality, high-resolution images for the most demanding needs of diagnostic radiology investigations. Due to these characteristics, it is the ideal machine for every hospital, clinic, and diagnostic center. 

Technical Specification

• Model: Starnuke 100 mA Fixed X-Ray Machine
• Radiography: 100 mA at 100 kVp
• Tube Current: F(0-3 mA), 25 mA, 50 mA, 75 mA & 100 mA
• Tube Voltage: 40-100 kVp (15 Steps)
• Timer: 0.02-5 Seconds (24 Steps)
• X-Ray Tube: Indian/Imported stationery anode
• Collimator: Manual light beam diaphragm
- Power Supply: Single Phase 230 + 10 V, 50 Hz 
- Rectification: Full wave rectified using silicon rectifiers  

Applications

1. Hospitals  
    For hospitals requiring an efficient and qualitative imaging system to assure proper diagnosis among the patients.

2. Clinics
Ideal for small to medium clinics where reliability and ease of operation are paramount in patient care.

3. Diagnostic Centers 
   It meets the high demand for diagnostic centers in order to provide fine resolution for accurate diagnoses.

4. Radiology Departments 
   This will be a good partner in the radiology departments since it improves the work of the workflow and enhances diagnostic capabilities.

X

Contact Us

Balram Singh Rajora (CEO)
Star Nuke Consulting Engineering Services Private Limited
Plot No. 25, Navkar Nagar, New Sanganer Road, Kalyanpura
Mansarovar, Jaipur - 302020, Rajasthan, India

Get Directions
Send Email
Share: